The New Hampshire Department of Environmental Services will hold a public hearing Dec. 3 on a revised version of its proposed changes to the state's subdivision and septic-system rules, Env-Wq 1000. Written comments on the revision are due Dec. 10.

The revision, called a draft final proposal and dated Nov. 12, keeps the main fixes the department proposed in July. It also adds changes that were not in the July version, including limits on which homeowners may install their own systems, new ways to size systems from water-meter readings, and rules for seasonal campgrounds. The notice of the hearing appeared in the state's Rulemaking Register on Nov. 19.

How to comment

The hearing is at 9 a.m. Dec. 3 in the Auditorium at the department's offices, 29 Hazen Drive, Concord, according to the notice. People can also join on Microsoft Teams (meeting number 261 306 317 595 862, password EJ2HM27F) or by phone at 1-603-931-4944, access code 657 121 895#.

Written comments are due Dec. 10 and can be sent by email to nhdesrules@des.nh.gov or through the NHDES Administrative Rules Public Comment Form on the state's online forms system. The contact for copies and questions is Aron Johnson, the department's legal coordinator, at aron.b.johnson@des.nh.gov or (603) 271-2464.

The department held a first hearing on the July version Aug. 31 and took written comments through Sept. 8, according to the original notice. State law, RSA 541-A:10, lets an agency seek more comment on an annotated draft final proposal before it files the final version.

What the revision keeps

The department described the July proposal as mainly corrections and clarifications to rules that took effect Feb. 1, 2026. The revision keeps these changes, with mostly wording edits:

Senior housing. Staff found that the Feb. 1 rules caused an unintended increase in bed sizing for senior housing and that the rule could be misread for other residential structures, the July notice says. Under Env-Wq 1016.01, senior-housing beds would be sized using the two-bedroom figures in the rule's table, multiplied by the number of units and divided in half.

Replacement systems. When plans show that an owner does not intend to build a proposed replacement system unless the existing one fails, Env-Wq 1004.03 would let the department make other required state permits a condition of construction instead of requiring proof of them up front. The July notice says this gives applicants an option other than requesting a waiver.

Local approval. The rules would state that an application must include proof of local approval where a municipality requires it, a requirement the current application form already contains. The revision keeps the exception for replacing a failed system.

Inspections. The inspection rule, renumbered Env-Wq 1004.05 in the revision, would allow one partial inspection when site constraints limit access, and more than one when a delay would threaten installed parts, access or safety on systems with flows of at least 2,500 gallons a day or more than one septic tank. Homeowners building a system for their own home would have to file the homeowner installation form before requesting an inspection. The revision adds an option to have a stakeout of the planned foundation, slab or gravel pad in place of the finished foundation at inspection, with the sewer pipe extended to within 5 feet of it.

Design plans. A new section, Env-Wq 1003.16, would treat the plan requirements in the rules as a minimum. The revision rewords it to put the burden on the applicant: a plan must include any additional information required for the applicant to demonstrate that all applicable design parameters have been met.

Tank size. Env-Wq 1010.01 sets minimum septic tank capacity at 1,250 gallons for up to four bedrooms, plus 250 gallons for each bedroom up to 12, with a formula for larger buildings. The revision applies the four-bedroom figure to a senior housing complex rather than a single senior housing unit.

What the revision adds

The draft final proposal adds several changes that were not in the July version:

  • Homeowners would not qualify for the state exemption that lets them install a system without a permit if the system serves more than one residence or serves a commercial use in addition to their home.

  • The rules for basing design flows on water-meter readings would add minimum metering periods, separate methods for residential and commercial uses, a ban on readings taken while a building is empty or a business is idle, and peaking factors of 2 or 3 for larger shared systems and commercial uses. The table of standard design flows adds or splits categories, including overnight and day boarding at dog kennels, coffee shop drive-throughs, delis and caterers.

  • A new section on seasonal campgrounds would require subdivision approval to convert a recreational campground to condominium or cooperative ownership.

  • A permitted designer could perform the groundwater mounding analysis that lets a system of more than 2,500 and up to 5,000 gallons a day use a single disposal field. For systems over 5,000 gallons a day, the analysis must be performed by a professional hydrogeologist, hydrologist or engineer who specializes in hydrogeology or hydrology.

  • A permitted installer or septage hauler could certify an existing septic tank for continued use, along with designers and licensed septic system evaluators.

  • The requirement to post a construction approval at the site where it is visible from a public way would be repealed, and later sections of Env-Wq 1004 renumbered.

Appeals and online filing

The proposal would implement Senate Bill 445 of the 2026 session for the first time, the July notice says. When the department suspends or revokes an approval, such as a subdivision or construction approval, it would issue a notice that can be appealed to the state Water Council instead of holding an administrative hearing. People who receive notice of an administrative fine under RSA 485-A:43 could also appeal to the Water Council.

Two forms could be submitted through NHEnviro, the department's new online filing system, and the proposal would update form web links after state website changes. The July notice says the rules affect septic designers and installers, owners of properties served by septic systems, people who subdivide land, and owners of developed waterfront property who sell it.

Sources: NHDES draft final proposal hearing notice, Notice 2026-159 and annotated draft final proposal text, Env-Wq 1000 (Nov. 12, 2026), published in the N.H. Rulemaking Register, Nov. 19, 2026; initial proposal rulemaking notice and initial proposal text (July 14, 2026); RSA 541-A:10.